description1
2023
DescriptionDescription
01Our DIN rail power supplies are engineered specifically for the rigorous demands of industrial automation and control systems. We offer a comprehensive range of series, including NDR, EDR, MDR, DR, and HDR, providing versatile solutions for diverse applications.
Wide Output Voltage Range: Our power supplies deliver a broad spectrum of output voltages, from 5V to 48V, ensuring compatibility with a wide array of industrial equipment.
Certified Quality: We prioritize safety and reliability. All our DIN rail power supplies carry essential certifications, including European CE, RoHS, and FCC, guaranteeing compliance with stringent international standards.
2023
FeaturesFeatures
01SpecificationsSpecifications
| Model | NDR-120-12 | NDR-120-24 | NDR-120-48 | |
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 10A | 5A | 2.5A | |
| Current range | 0~10A | 0~5A | 0~2.5A | |
| Rated power | 120W | 120W | 120W | |
| Ripple and noise (maximum) | 100mVp-p | 120mVp-p | 150mVp-p | |
| Voltage adjustment range | 12~14V | 24~28V | 48~55V | |
| Voltage accuracy | ±2.0% | ±1.0% | ±1.0% | |
| Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | |
| Load adjustment rate | ±1.0% | ±1.0% | ±1.0% | |
| Start and rise time | 1200ms,60ms/230VAC 2500ms,60ms/115VAC(full load) | |||
| Hold time (Typ.) | 16ms/230VAC 10ms/115VAC(full load) | |||
| Input | Voltage range | 90-264VAC 127-370VDC [DC input can be achieved by connecting AC/L (+), AC/N (-)] | ||
| Frequency range | 47~63Hz | |||
| Efficiency (Typ.) | 85.50% | 88% | 89% | |
| AC current (Typ.) | 2.25A/115VAC 1.3A/230VAC | |||
| Surge current (Typ.) | 20A/115VAC 35A/230VAC | |||
| Leakage current | <1mA/240VAC | |||
| Protection | Overload | 105%~130% of rated output power | ||
| Protection mode: constant current mode, abnormal load bar | ||||
| Overvoltage | 14~17V | 29~33V | 56~65V | |
| Protection mode: Turn off output, normal output can be restored after power restart | ||||
| Over temperature | Turn off output, normal output can be restored after power restart | |||
| Environment | Working temperature | -20~+70℃ | ||
| Working humidity | 20~95%RH,non-condensing | |||
| Storage temperature and humidity | -40~+85℃,10~95%RH | |||
| Temperature coefficient | ±0.03%/℃(0~50℃) | |||
| Vibration resistance | Component: 10~500Hz, 2G10 minutes/cycle, X, Y, Z each for 60 minutes; Installation: Compliant with IEC60068-2-6 | |||
| Safety regulations and electromagnetic compatibility | Safety regulations | UL508, EAC TP TC 004, TUV EN62368-1 certification passed; (Meets EN60204-1) | ||
| Voltage resistance | I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC | |||
| Insulation impedance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC/25℃/70% RH | |||
| Electromagnetic compatibility emission | Compliant with EN55032 (CISPR32), EN61204-3 CIass B,EN61000-3-2,-3,EAC TP TC 020 | |||
| Electromagnetic compatibility immunity | Complies with EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, A-grade heavy industry standard EAC TP TC 020 | |||
| Other | MTBF | ≥456.3K hrs. MIL-HDBK-217F(25℃) | ||
| Size | 40*125.2*113.5mm(W*H*D) | |||
| Packing | 0.6Kg; 20pcs/13Kg/1.16CUFT | |||
| Note | 1. Unless otherwise specified, all specification parameters are measured at an input of 230VAC, rated load, and an ambient temperature of 25 ℃. | |||
| 2. Ripple and noise measurement method: Use a 12 "twisted pair cable, with terminals connected in parallel with 0.1uf and 47uf capacitors, and measure at a bandwidth of 20MHz. | ||||
| 3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate. | ||||
| 4. The power supply should be considered as a part of the internal components of the system and should be confirmed for electromagnetic compatibility in conjunction with the terminal equipment. | ||||
| 5. Installation distance: When permanently loaded with full power, it is recommended to have a top distance of 40mm, a bottom distance of 20mm, and a distance of 5mm on both sides. If the adjacent device is a heat source, the recommended spatial distance is 15mm. | ||||
| 6. Under low input voltage, the output needs to be reduced | ||||
| 7.When the altitude exceeds 2000 meters (6500 feet), the ambient temperature of the fanless model decreases proportionally every 3.5 ℃/1000m, while the ambient temperature of the fanned model decreases proportionally every 5 ℃/1000m. | ||||
mandy@huyssenpower.com
0086-13570841067
AC/DC Power Supply
AC to DC Power Supply 0-48V 4000W with High PFC
3000W 60V Switching Power Supply
DC 12V 83.3A 1000W AC/DC Switch Mode Power Supply
AC to DC 36V 1500W Switch Mode Power Supply
AC DC Power Supply S Series
SMPS DC 60V 20A 1200W Switching Power Supply
ACDC 24V 500W High Quality Switching Power Supply
Din Rail Power Supply 12V 60W MDR-60-12
24V 60W Din Rail power supply MDR-60-24
12V 240W din rail power supply
DR-120-24 Din rail power supply
NDR-480-48 Din rail power supply
NDR-120-24 Industrial Din Rail 120W 24V 5A Power supply
DC Power Supply
DC 100V 15KW Programmable Power Supply
app_imgs
app_imgs
DC 200V 60KW programmable power supply
DC 100V 1000A 100KW programmable power supply
Open Frame Power Supply
On Board Charger
Buck Converter DC input 18-36V to DC 5V60A 300W SD-350C-5
Buck Converter DC Input 200-500V to DC Output 3kW 0-32V for EV


top